use Ticker to avoid request blocking

This commit is contained in:
Cedric Girard 2019-07-31 21:14:49 +02:00
parent 27ca17f5e3
commit 01551bb521
Signed by: X-dark
GPG Key ID: E7D0E125DB9519E4
1 changed files with 76 additions and 67 deletions

View File

@ -1,6 +1,7 @@
#include <Arduino.h>
#include <Wire.h>
#include <Preferences.h>
#include <Ticker.h>
#include <WiFi.h>
#include "wifi_login.h"
@ -20,6 +21,9 @@ WebServer server(80);
Preferences preferences;
Ticker metricsReader;
Ticker baselineReader;
U8G2_SSD1327_WS_128X128_1_4W_HW_SPI u8g2(U8G2_R0, /* cs=*/ 17, /* dc=*/ 3, /* reset=*/ 16);
@ -73,6 +77,69 @@ float temp(NAN), hum(NAN), pres(NAN);
uint16_t TVOC_base, eCO2_base;
bool baseline_set = false;
void readMetrics() {
//Clear screen
u8g2log.print("\f");
//Read Temperature, humidity and pressure
bme.read(pres, temp, hum, tempUnit, presUnit);
//Read Air Quality
sgp.setHumidity(getAbsoluteHumidity(temp, hum));
if (! sgp.IAQmeasure()) {
u8g2log.print("Air Quality Measurement failed\n");
return;
}
u8g2log.print("Temp: ");
u8g2log.print(temp);
u8g2log.print("°"+ String(tempUnit == BME280::TempUnit_Celsius ? 'C' :'F'));
u8g2log.print("\nHum: ");
u8g2log.print(hum);
u8g2log.print("% RH");
u8g2log.print("\nPres: ");
u8g2log.print(pres);
u8g2log.print("hPa\n");
u8g2log.print("TVOC ");
u8g2log.print(sgp.TVOC);
u8g2log.print(" ppb\n");
u8g2log.print("eCO2 ");
u8g2log.print(sgp.eCO2);
u8g2log.print(" ppm\n");
}
void readBaseline() {
if (! sgp.getIAQBaseline(&eCO2_base, &TVOC_base)) {
u8g2log.print("Failed to get baseline readings\n");
return;
}
u8g2log.print("Baseline values: eCO2: 0x");
u8g2log.print(eCO2_base, HEX);
u8g2log.print(" & TVOC: 0x");
u8g2log.print(TVOC_base, HEX);
u8g2log.print("\n");
//Init Non Volatile Storage
// Namespace name is limited to 15 chars.
// RW-mode (second parameter has to be false).
preferences.begin("env-monitor", false);
preferences.putBool("baseline_set",true);
preferences.putUShort("TVOC_base", TVOC_base);
preferences.putUShort("eCO2_base", eCO2_base);
preferences.end();
//Next baseline reading in 1h
baselineReader.once(3600, readBaseline);
}
void sendMetrics() {
String message = "# ESP32 Env monitor Prometheus metrics\n\n";
@ -207,79 +274,21 @@ void setup() {
//delay to allow setup output reading
delay(10000);
//read Metrics once
readMetrics();
//and then read Metrics every minutes
metricsReader.attach(60, readMetrics);
//First baseline reading after 12 hours
baselineReader.once(3600 * 12, readBaseline);
}
int elapsed_minutes = 0;
int elapsed_hours = 0;
void loop() {
server.handleClient();
//Clear screen
u8g2log.print("\f");
//Read Temperature, humidity and pressure
bme.read(pres, temp, hum, tempUnit, presUnit);
//Read Air Quality
sgp.setHumidity(getAbsoluteHumidity(temp, hum));
if (! sgp.IAQmeasure()) {
u8g2log.print("Air Quality Measurement failed\n");
return;
}
u8g2log.print("Temp: ");
u8g2log.print(temp);
u8g2log.print("°"+ String(tempUnit == BME280::TempUnit_Celsius ? 'C' :'F'));
u8g2log.print("\nHum: ");
u8g2log.print(hum);
u8g2log.print("% RH");
u8g2log.print("\nPres: ");
u8g2log.print(pres);
u8g2log.print("hPa\n");
u8g2log.print("TVOC ");
u8g2log.print(sgp.TVOC);
u8g2log.print(" ppb\n");
u8g2log.print("eCO2 ");
u8g2log.print(sgp.eCO2);
u8g2log.print(" ppm\n");
//Get Baseline readings every hour
if (elapsed_minutes == 60) {
elapsed_minutes = 0;
elapsed_hours++;
//only get baseline after running for 12h
if (elapsed_hours >= 12 ){
if (! sgp.getIAQBaseline(&eCO2_base, &TVOC_base)) {
u8g2log.print("Failed to get baseline readings\n");
return;
}
u8g2log.print("Baseline values: eCO2: 0x");
u8g2log.print(eCO2_base, HEX);
u8g2log.print(" & TVOC: 0x");
u8g2log.print(TVOC_base, HEX);
u8g2log.print("\n");
//Init Non Volatile Storage
// Namespace name is limited to 15 chars.
// RW-mode (second parameter has to be false).
preferences.begin("env-monitor", false);
preferences.putBool("baseline_set",true);
preferences.putUShort("TVOC_base", TVOC_base);
preferences.putUShort("eCO2_base", eCO2_base);
preferences.end();
}
}
//wait 1min
delay(60000);
elapsed_minutes++;
}
// vim: set ts=2 sw=2 et: